Introduction to Flanged Split Tee
Flanged Split Tees are full-encirclement branch fittings designed for installation around an existing pipeline. Their split-body construction generally consists of two matching sections positioned around the carrier pipe and joined using an approved welding or mechanical assembly procedure. A flanged branch outlet provides a connection for valves, tapping equipment, or branch piping.
These fittings are commonly associated with hot-tapping operations, where a new branch connection may be created without removing the existing pipeline section. Depending on the design and approved procedure, the fitting can also provide local reinforcement around the branch opening.
Flanged Split Tees are manufactured in different run sizes, branch sizes, pressure ratings, material grades, flange facings, and wall thicknesses. Because their dimensions are often project-specific, selection must follow the governing piping code, design calculations, pipeline data, applicable flange standard, and manufacturer-approved drawing.
Flanged Split Tee – Applications and Performance
Flanged Split Tees are used in oil and gas pipelines, refineries, petrochemical facilities, water transmission systems, power plants, and industrial process piping. They support branch creation, pipeline modification, equipment connection, bypass installation, and approved hot-tapping operations.
Performance depends on correct matching with the existing pipe diameter, wall thickness, material, operating pressure, temperature, fluid service, and external loads. The branch flange must also be compatible with the connecting valve or piping component.
Installation on an operating pipeline requires detailed engineering evaluation, qualified welding or assembly procedures, controlled tapping operations, inspection, and testing. Material compatibility, weld integrity, flange alignment, gasket selection, and bolt tightening are essential for maintaining pressure containment and dependable long-term service.
| Flanged Split Tee Specifications | |
|---|---|
| Size | Available in full-size and reducing branch configurations, with run and branch sizes selected according to pipeline dimensions and project requirements |
| Pressure Rating | Selected according to pipeline design pressure, branch flange rating, material, operating temperature and applicable project specification |
| Design Standards | ASME B31.3, ASME B31.4 and ASME B31.8 may be applied according to piping or pipeline service and project design requirements |
| Flange Standards | ASME B16.5 for applicable flange sizes and ASME B16.47 for applicable large-diameter flange connections, as specified by the project |
| Fitting Type | Full-encirclement split tee consisting of two matching run halves with a flanged branch connection |
| Configuration | Available with full-size or reducing branch outlets and manufactured to match the outside diameter and wall requirements of the existing pipeline |
| Connection Type | Split run sections are field welded around the existing pipeline, while the branch incorporates a flanged connection for valves and hot-tapping equipment |
| Flange Facing | Raised Face (RF), Ring Type Joint (RTJ) or other specified facing according to flange standard, pressure rating and service requirements |
| Application | Used for hot tapping, branch connections, pipeline modifications, line intervention and other operations where pipeline shutdown may be undesirable |
| Manufacturing | Factory fabricated or formed to approved design calculations, dimensional requirements, welding procedures, inspection requirements and project specifications |
| Material Grades | |
| Carbon Steel | ASTM A234 WPB and other suitable carbon steel fitting materials may be specified according to pipeline design and service requirements |
| High-Yield Steel | ASTM A860 WPHY grades may be specified for high-strength pipeline applications, subject to design and welding requirements |
| Branch Flange | ASTM A105 or ASTM A694 high-strength forged carbon steel grades may be specified according to flange rating and pipeline service |
| Low-Temperature Steel | Suitable low-temperature carbon steel materials may be selected where required by minimum design temperature and impact-toughness requirements |
| Sour Service | Materials may be selected and qualified for sour-service applications in accordance with applicable ISO 15156 / NACE requirements and project specifications |
| Custom Materials | Other compatible materials may be supplied according to pipeline material, design calculations, welding compatibility and approved project requirements |
Get the best quote today.
Product Categories
Flanges
Flanged Split Tee Standards & Pressure Rating
| Flanged Split Tee Standards & Pressure Rating | |
|---|---|
| ASME B31.3 | Applicable to process piping installations where the split tee is designed and qualified for process piping service |
| ASME B31.4 | Applicable to liquid pipeline systems, with split tee design and reinforcement determined according to pipeline and project requirements |
| ASME B31.8 | Applicable to gas transmission and distribution pipeline systems, including requirements relevant to welded full-encirclement fittings |
| ASME B16.5 | Used for applicable branch flange connections through NPS 24, according to flange size, class, material and service conditions |
| ASME B16.47 | Used for applicable large-diameter branch flange connections above NPS 24, where specified by the project |
| Pressure Classes | Class 150, 300, 600, 900 and 1500 are commercially available for certain split tee designs; actual rating depends on fitting design, flange class and project requirements |
| Design Pressure | Determined by pipeline design pressure, design factor, material strength, wall thickness, temperature and applicable piping or pipeline code |
| Branch Configuration | Available in full-branch and reducing-branch configurations according to run size, branch size and hot-tapping requirements |
| Flange Facing | Raised Face (RF), Ring Type Joint (RTJ) or other specified facing compatible with the mating valve and applicable flange standard |
| Welding | Fabrication and field welding procedures are qualified according to applicable welding codes, pipeline requirements and approved project procedures |
| Inspection & Testing | Nondestructive examination, pressure testing and inspection requirements are specified according to fitting design, applicable code and project specification |
| Common Applications | Hot tapping, line stopping, pipeline branching, system modification, pipeline intervention and connections to existing pressurized pipelines |
| Important Selection Factors | Run size, branch size, pipeline outside diameter, wall thickness, material, flange class, design pressure, temperature and operating service |
Flanged Split Tee Dimensions
| Flanged Split Tee Class 150 Dimensions (mm) | |||
|---|---|---|---|
| Size (NPS) | DN | Overall Length (L) | Centerline-to-Flange Face (H) |
| 4 | 100 | 273 | 165 |
| 6 | 150 | 356 | 202 |
| 8 | 200 | 412 | 240 |
| 10 | 250 | 508 | 280 |
| 12 | 300 | 550 | 322 |
| 14 | 350 | 660 | 347 |
| 16 | 400 | 762 | 395 |
| 18 | 450 | 838 | 420 |
| 20 | 500 | 914 | 447 |
| 22 | 550 | 1016 | 477 |
| 24 | 600 | 1092 | 512 |
| Flanged Split Tee Class 300 Dimensions (mm) | |||
|---|---|---|---|
| Size (NPS) | DN | Overall Length (L) | Centerline-to-Flange Face (H) |
| 4 | 100 | 273 | 162 |
| 6 | 150 | 356 | 207 |
| 8 | 200 | 412 | 242 |
| 10 | 250 | 508 | 280 |
| Flanged Split Tee Class 600 Dimensions (mm) | |||
|---|---|---|---|
| Size (NPS) | DN | Overall Length (L) | Centerline-to-Flange Face (H) |
| 4 | 100 | 273 | 182 |
| 6 | 150 | 356 | 227 |
| 8 | 200 | 412 | 270 |
| 10 | 250 | 508 | 320 |
| Flanged Split Tee Class 900 Dimensions (mm) | |||
|---|---|---|---|
| Size (NPS) | DN | Centerline-to-Flange (CLF) | Height (H) |
| 4 | 100 | 189.3 | 312.1 |
| 6 | 150 | 237.7 | 398.7 |